Filters
Close

Copeland Emerson Control Link ACC Kit, UL Recognized 30A, Door Frame Temp & Dewpoint Sensor

SKU: 815-6107

Download Installation and Operation Manual

 

ACC Kit - Control Link ACC 30Amp, Door Frame Temp Sensor and Dewpoint Sensor

The Control Link ACC Anti-Condensate Controller System is a controller for anti-sweat heaters inside glass door cases and can be used either as a stand-alone device or networked with the E2 controller over the MODBUS network.

The Control Link ACC varies the anti-sweat heaters based on the temperature of the door frame and surrounding dewpoint, providing the most efficient control possible in order to maximize energy savings.

Kit Includes:

  • 1 x Control Link ACC 30Amp UL Recognized 815-6105*
  • 1 x Door Frame Temperature Sensor 281-0001
  • 1 x Dewpoint Sensor 814-6115

*P/N 815-6105 UL Recognized version 18A/26A/30A requires an additional heat sink.

Control Link ACC Specifications:

    • Temperature Range: Storage Temp: -40°C to 65°C (-40°F to 149°F)
    • Ambient Operating Temperatures (UL Recognized):
      • -40°C to +25°C (-40°F to 77°F) up to 30A (with additional heat sink with max thermal resistance of 0.51°C/Watt (0.92°F/Watt)
      • -40°C to +40°C (-40°F to 104°F) up to 26A (with additional heat sink with max thermal resistance of 0.51°C/Watt (0.92°F/Watt)
      • -40°C to +65°C (-40°F to 149°F) up to 18A (with additional heat sink with max thermal resistance of 0.51°C/Watt (0.92°F/Watt)
    • Input Voltage: 120/240 Nominal (102VAC to 264VAC) 50/60 Hz
    • Humidity: 5% to 95% non-condensing
    • Door Frame Temp Sensor: +/- 0.4°C of 0 to 80°C (+/- .72°F of 32°F to 176°F) up to +/- 0.6°C at -40°C and 120°C (+/- 1.08°F at -40°F and 248°F)
    • Dewpoint Sensor:
      • +/- 1°C (+/- 1.8°F) over RH of 40 to 95% RH
      • +/- 4°C (+/- 7.2°F) over RH of 10 to 40% RH
    • Agency Approvals: UL916 Open Energy Management Equipment, File E118489, FCC Part 15 Class A (non-intentional radiators), CE, RoHS

Part Number: 815-6107